KLNE SunTeams Solar Inverter Fault & Error Messages
No.
Cause
Remedy
1
< Disconnect Grid > Possible causes: Stop power supply from the grid; AC circuit breaker is disconnected; The both sides of AC circuit breaker are in poor contact.
View Remedy
Idenitfy whether the grid stops power supply; Identify whether the AC circuit breaker is closed; Identify whether the breakover of the two terminals of AC circuit breaker is good; If there are no above problems, please contact your distributor or customer service department.
2
< Grid V Fault > Possible causes: The grid voltage exceeds the scope prescribed in the local regulations.
View Remedy
When reporting error, check whether the grid voltage of the inverter is within the range prescribed in local regulations; Report this problem to the distributor or customer service department.
3
< Grid F Fault > Possible causes: The grid frequency exceeds the scope prescribed in the local regulations.
View Remedy
Whether this problem is always existing or intermittently existing; Report this problem to the distributor or customer service department.
4
< Low Isolation > Possible causes: The ground wires at the AC terminal are in poor contact.
View Remedy
Check whether the ground wire of AC is in good contact; If there is no problem, please contact your distributor or customer service department.
5
< High PV Voltage > The actual voltage at the DC side exceeds the specified range of the inverter.
View Remedy
Check whether the actual voltage at the DC side is within the specified range of the inverter; If complying with the range of the inverter voltage, please contact the distributor or customer service department.
6
< High Ground I > The possible cause is that there is leakage at the AC side.
View Remedy
Disconnect the circuit breakers at the DC side and AC side and check whether there are damages to the cables and circuit breakers at the AC side.
7
< High Temperature > The ambient temperature of the inverter is too high.
View Remedy
Idenitfy whether the ambient temperature is abnormal; Identify whether the inverter has sufficient heat dissipation space; Identify whether cooling fin of the inverter is blocked; If the external environment is normal, please contact the distributor or customer service.
Here are some more fault messages that you may see on the KLNE SunTeams Solar Inverter display screen and their descriptions.
Display
Operation
System Fault
Disconnect Grid
View Operation
Disconnect Grid
Grid V Fault
View Operation
Grid voltage out range
Grid F Fault
View Operation
Grid frequency out range
Low Isolation
View Operation
Low input isolation
High PV Voltage
View Operation
PV input voltage high
High Ground I
View Operation
GFCI active
High Temperature
View Operation
Temperature too high
Inverter Fault
EEPROM Damaged
View Operation
EEPROM has problem
Please initiate
View Operation
System has not been initiated at the first time
GFCI Damaged
View Operation
GFCI device damaged
Sensor Damaged
View Operation
Output AC sensor damaged
SCI Damaged
View Operation
The communication between the two MCU fault
Not Consistent
View Operation
The data is not the same for the two MCU
High DC INJ
View Operation
Output DC Injection Too High
Relay Damaged
View Operation
Output Relay Failure
High Bus Voltage
View Operation
DC Bus Voltage Is Too High
Auto Test Failed
View Operation
Auto test failed
2.5 V Ref Fault
View Operation
2.5 V Reference Voltage Inside has problem